TM 9-2350-247-20-3
REPLACE NBC M18 FILTER (M548A3) Continued
0536 00
INSTALLATION
1.
Install M18 filter (1) in two clamps (2) on manifold (3) with AIR FLOW arrow pointing toward hose (4) on right side of
M18 filter. Secure clamps with two nuts (5).
2.
Install hose (4) and hose (6) on ends of M18 filter (1) with clamp (7) and clamp 8(8).
3.
Install M18 filter (9) in two clamps (2) on manifold (3) with AIR FLOW arrow pointing toward hose (10) on left side of
M18 filter. Secure clamps with two nuts (5).
4.
Install hose (10) and hose (11) on ends of M18 filter (9) with clamp (12) and clamp (13).
FOLLOW-THROUGH STEPS
1.
Install NBC manifold (WP 0533 00).
2.
Install portable fire extinguisher (see your -10).
3.
Connect both battery negative leads (WP 0292 00).
END OF TASK
0536 00-3/4 blank