TM 9-2350-247-20-3REPLACE NBC ORIFICE CONNECTOR ASSEMBLY AND BRACKET (M548A3) —Continued0538 00INSTALLATION1. Place bracket (3) on cowl stiffener and secure with screw (7), new lock washer (5), washer (6), and new lock nut (4).2. Install outlet valve disk (10) on orifice connector (9).3. Install outlet valve cover (8) on orifice connector (9).4. Install orifice connector (9) in bracket (3) with retaining ring (1).5. Install quick disconnect coupling (10) on orifice connector assembly (11).END OF TASK0538 00-4