TM 9-2350-247-20-3REPLACE NBC M19 PARTICULATE FILTER UNIT (M548A3) — Continued 0535 00INSTALLATION1. Install M19 particulate filter (1) in precleaner housing (2). Make sure felt gasket on M19 particulate filter is facing themanifold (3).2. Install two air flow control caps (4) on two outlets (5) on manifold (3).3. Install manifold (3) on precleaner housing (2). Secure with four screws (6) and new lock washers (7).FOLLOW-THROUGH STEPS1. Install M1A1-19 precleaner (WP 0534 00).2. Connect both battery negative leads (WP 0292 00).END OF TASK0535 00-3/4 blank