TM 9-2350-247-20-2
REPLACE TRACK TENSION ADJUSTER AND MOUNT -- Continued
0356 00
REMOVAL
NOTE
If carrier has new type spindle, omit Step 1 and Step 3.
1.
2.
Remove screw (1) and washer (2) from mount (3).
3.
Remove idler wheel arm assembly, with track tension adjuster attached (WP 0354 00).
4.
Remove screw (4) and washer (5) from shaft on idler arm.
5.
Remove two screws (6) from mount (3). Loosen screw (7). Rotate mount and remove screw (7).
6.
Pull track tension adjuster (8) down. Remove mount (3) from adjuster.
7.
Remove track tension adjuster (8) from shaft on idler arm.
8.
Remove grease fitting (9) and relief valve (10) from track tension adjuster (8).