TM 9-2350-247-20-2
REPLACE DIFFERENTIAL SWITCH LEAD (M548A1)
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Maintenance Level
References
Unit
See your -10
Tools and Special Tools
Equipment Condition
General Mechanic's Tool Kit (WP 0541 00, Item 57)
Materials/Parts
Engine stopped (see your -10)
Lock nut
Center floor plates removed (WP 0394 00)
Personnel Required
Center seat raised (see your -10)
Hull bottom access cover removed (WP 0383 00)
Unit Mechanic
REMOVAL
1.
Remove lock nut (1), clamp (2), and screw (3) from clamp (4). Discard lock nut.
2.
Disconnect circuit 328 lead (5) from differential high oil temperature switch (6) and power plant wiring harness (7).
Remove lead.
3.
If replacing circuit 328 lead (5), remove clamp (2) from lead.