TM 9-2350-247-20-2
REPLACE AUXILIARY POWER (SLAVE) RECEPTACLE -- Continued
0303 00
1.
Install new gasket (17) and auxiliary power receptacle (4) in bulkhead (8). Secure with four screws (1), washers (3),
and new lock nuts (19).
2.
Install retaining plate (14) with four screws (16), washers (15), and new lock nuts (13).
3.
Install new gasket (17) and auxiliary power receptacle (4), with four screws (1), new lock washers (2), and washer
(3) on retaining plate (14).
4.
Install ground lead (10) on negative post (18) of auxiliary power receptacle (4). Secure with screw (11) and new lock
washer (12).
5.
Install circuit 50 lead (9) on positive post (5) of auxiliary power receptacle (4). Secure with screw (6) and new lock
washer (7).
0303 00-4
Change 1