TM 9-2350-247-20-2
REPLACE GENERATOR-TO-REGULATOR WIRING HARNESS (M548A1)
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
References
Maintenance Level
Unit
See your -10
Tools and Special Tools
Equipment Condition
General Mechanic's Tool Kit (WP 0541 00, Item 57)
Engine stopped (see your -10)
Carrier blocked (see your -10)
Personnel Required
Unit Mechanic
Power plant rear access door removed (see your -10)
REMOVAL
1.
Disconnect generator-to-regulator connector (1) from generator (2).
2.
Disconnect regulator-to-generator connector (3) from regulator (4).
3.
Remove generator-to-regulator wiring harness (5) from power plant.
INSTALLATION
1.
Install generator-to-regulator wiring harness (5) in power plant.
2.
Connect generator-to-regulator connector (1) to generator (2).
3.
Connect regulator-to-generator connector (3) to regulator (4).