TM 9-2350-247-20-2
REPAIR WIRING HARNESS -- Continued
0294 00
c.
If large diameter lead (1), fill crimp (2) on terminal (3) with solder. Use soldering gun. Insert lead into melted
solder in crimp. Allow to cool.
d.
If small diameter lead (4), position terminal (5) on lead. Crimp terminal on lead. Use crimping tool from electrical
tool kit.
e.
Heat shrink those leads with insulated sleeving (6) on terminal (7). Use heat gun.
4.
Install multiple connectors the same way as single connectors. See Installation Procedure Step 2 and Step 3.
5.
If removed, install Y-type adapters and dummy plugs.
a.
Install Y-type adapter (8) on harness leads (9).
b.
Install dummy plugs (10) in male or female connector (11).
0294 00-5