TM 9-2350-247-20-1
STE/ICE-R STARTER CIRCUIT TROUBLESHOOTINGContinued
0109 00
4CY
1. Connect black clip of test probe cable W2 to the negative battery
terminal.
2. Connect red clip of test probe cable W2 to the positive terminal of
starter.
3. Press and release test button.
4. Crank engine and read displayed voltage.
5. Is starter voltage above 17 volts?
YES
NO
GO TO EY (PAGE 0109 00-6)
5CY
1. Move red clip of test probe cable W2 to ground terminal of starter.
2. Crank engine and read displayed voltage.
3. Is voltage drop less than 18 volts?
YES
NO
5CYN
1. Clean, inspect, and repair cables as
needed.
2. Verify no faults found.
6CY
1. Replace starter (WP 0253 00 or (WP 0254 00).
2. Verify no faults found.
DY
1. Check to see if resistance is high.
2. Is resistance high?
YES
NO
DYN
1. Repair short circuit in starter circuit.
2. Verify no faults found.
2DY
1. Attempt to start engine while listening for clicking of starter
solenoid.
2. Does starter solenoid click?
YES
NO
2DYN
1. Check switches, wiring, relays, and
circuit breakers to starter solenoid.
2. Verify no faults found.
0109 00-4