TM 9-2350-247-20-1STE/ICE-R STARTER CIRCUIT TROUBLESHOOTING—Continued 0109 002Y1. Check if starter circuit resistance is within 5 to 27.2. Is starter circuit resistance within 5 to 27?YESNOGO TO CY (PAGE 0109 00-3)3Y1. Check batteries to make sure they are fully charged TM9-6140-200-14.2. Verify no faults found.BY1. Check to see if E013 Is displayed.2. Is E013 displayed?YESNOBYN1. Check batteries to make sure they arefully charged TM 9-6140-200-14.2. Verify no faults found.2BY1. Crank engine (see your -10).2. Does any message appear other than GO?YESNOGO TO DY (PAGE 0109 00-4)3BY1. Check how many times E013 has been displayed2. Is this the third time E013 was displayed?YESNO3BYN1. Repeat this part of troubleshooting.2. Verify no faults found.4BY1. Turn off all electrical equipment.2. Set test select switches to 90.3. Press and hold test until CAL appears on display.4. Is offset value within limits of -225 to +225?YESNO4BYN1. Go to offset fault isolation TM9-4910-571-12&P.2. Verify no faults found.0109 00-2
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business