TM 9-2350-247-20-1STE/ICE-R CHARGING CIRCUIT TROUBLESHOOTING—Continued 0108 00OUTPUT CURRENT1. Set test select switches to 01.2. Press and release test button.3. When CON appears, set test select switches to 90.4. Press and release test button.5. Turn on lights and accessories.6. Set engine speed to 1000 to 1200 rpm.7. Is output current below 70 amps?YESNOBYN1. Go to battery/generator indicatormalfunctions (WP 0052 00).2. Verify no faults found.2BY1. Stop engine (see your -10).2. Turn off lights and accessories.3. Adjust generator drive belts (WP 0241 00 or WP 0245 00).4. Are drive belts ok?YESNO2BYN1. Replace generator drive belts(WP 0241 00 or WP 0245 00).2. Verify no faults found.3BY1. Check operation of generator field switch (WP 0288 00).2. Was generator field switch repaired?YESNO3BYN1. Check charging system cables forloose or corroded connections.2. Verify no faults found.4BY1. Verify no faults found.0108 00-2