TM 9-2350-247-20-1STE/ICE-R CHARGING CIRCUIT TROUBLESHOOTING—Continued 0108 00FIELD CURRENT1. Install current probe around circuit 1 lead of generator toregulator cable.2. Point arrow on current probe toward generator.3. Set test select switches to 01.4. Press and release test button.5. When PASS appears, set test select switches to 90.6. Press and release test button.7. Raise engine speed to 1000 to 1200 rpm and read rpm display.8. Stop engine (see your -10).9. Is current below 6 amps?YESNOCYN1. Go to charging system malfunctions(WP 0023 00).2. Verify no faults found.2CY1. Check continuity of cables from regulator to generator.2. If cables are ok, go to charging system malfunctions(WP 0023 00).3. Verify no faults found.0108 00-3/4 blank