TM 9-2350-287-20-17-12 AIR CLEANER BLOWER MOTOR RELAY REPLACEMENT.This Task Covers:a. Removalb. InstallationInitial Setup:Tools/Test Equipment:l MASTER switch set to OFF (refer tol General mechanic’s tool kit (Item 24,TM 9-2350-287-10).Appendix I)l Battery ground leads disconnected(para 7-41).Materials/Parts:l Driver's portable instrument panel removedl Lockwasher (2) (Item 129, Appendix H)(para 7-6).Equipment Conditions:l Vehicle parked on level ground (refer toTM 9-2350-287-10).a.1.2.3.4.b.1.2.3.4.REMOVALDisconnect electrical connector (3) from air cleaner blower motor relay (1).Remove nut (8), ground lead end (9), and Iockwasher (10) from mount (4). Discard Iockwasher.Remove nut (2) and relay (1) from driver’s compartment wall.Remove nut (7), washer (6), bracket (5), three mounts (4), ground lead (11 ), and Iockwasher (12) from driver’scompartment wall. Discard Iockwasher.INSTALLATIONInstall new Iockwasher (12), ground lead (11), three mounts (4), and bracket (5) on driver’s compartment wallwith washer (6) and nut (7).Install relay (1) on driver’s compartment wall with nut (2).Install new lockwasher (10) and ground lead end (9) on mount (4) with nut (8).Connect electrical connector (3) to relay (1).7-38