7-11. CIRCUIT BREAKER PANELS AND CIRCUIT BREAKER REPLACEMENT
7-12 AIR CLEANER BLOWER MOTOR RELAY REPLACEMENT
TM-9-2350-287-20-1 Carrier Ammunition Tracked M992A21 (2350-01-352-3021) EIC:AE6 Manual
Page Navigation
702
703
704
705
706
707
708
709
710
711
712
TM 9-2350-287-20-1
7
-
11
.
CIRCUIT
BREAKER
PANELS
AND
CIRCUIT
BREAKER
REPLACEMENT
(continued)
.
3.
Install eight
circuit breaker
s (23) on mounting bracket (19) using two nuts (22), screws (17), new Iockwashers
(21 ), and washers (20).
d.
INSTALLATION
1.
Install two mounting brackets (6 and 19) in drivers compartment with four screws (15), new Iockwashers (14),
and washers (13).
2.
Connect 16 electrical leads (18) to eight
circuit breaker
s (23) on mounting bracket (19).
3.
Connect eight electrical leads (4) to four
circuit breakers
(5) and two electrical leads (1) to circuit breaker (3)
on mounting bracket (6).
FOLLOW-ON TASKS:
l
Install driver’s instrument panel (para 7-9).
l
Install portable instrument panel (para 7-6).
l
Connect battery ground cables (para 7-41).