TM 9-2350-287-20-1
2-7.
SERVICING AND CONNECTING BATTERIES (continued).
8.
Connect wiring harness 12330348 lead 7(37) and wiring harness lead 10897992 lead 7(40) to STE/ICE shunt
(29) with two screws (39) and Iockwashers (38).
9.
Install wiring harness 12330348 lead 7 (37)
to positive terminal (8) with screw (9) and nut
(12).
10.
Install wiring harness 10897992 lead 7 (40)
to negative terminal (18) with screw (19) and
nut (17).
FOLLOW-ON MAINTENANCE:
l Close battery access doors (refer to TM 9-2350-
287-10).
2-10