TM 9-2350-287-20-12-19. TROUBLESHOOTING CHART (continued).Iw. AFES, CREW (continued).(7) AFES MEGOMETER TROUBLESHOOTINGPROCEDURES (continued).CONTINUED FROM GTroubleshoot personnel ventilation blowersystem (para 2-19o.(1). Return VENTFANswitch to ON. Verify problem is solved.Replace SCEA (para 21-15). Return VENTFAN switch to ON. Verify problem is solved.CONTINUED FROM STEP FH. 1. Turn the CREW AFES T/A panelMaintenance switch to the vertical positionand check the green POWER ON lamp tomake sure the AFES is not powered.2. Disconnect SCEA from the test box andreturn the AFES to its normal configuration.3. Turn the CREW AFES T/A panel mainte-nance switch to the horizontal position andcheck the green POWER ON lamp to verify theAFES is powered.4. Check the CREWAFES T/A panel for FIREEXT fault LED’s.Is faulty fire extinguisher indicated on CREWAFES T/A panel?Problem is solved.I. 1. Locate the fire extinguisher indicated asfaulty by the CREW AFES T/A panel LED anddisconnect it from the harness 12352315 W3.Continued on next page2-365