TM 9-2350-287-20-12-19. TROUBLESHOOTING CHART (continued).m. BILGE PUMP (continued).(1) BILGE PUMP DOES NOT OPERATE. All otherelectrical systems operate (continued).CONTINUED FROM GG. 6. Turn MASTER switch OFF (refer toTM 9-2350-287-10).Is voltage indicated?Repair wire 450 or replace harness12268104 (para 7-61 ). Verify problem issolved.H. 1. Reconnect wire 450 to circuit breakeroutput.2. Disconnect wire 10B of wire harness12376405 from circuit breaker no. 2 input.3. Place red lead of multimeter in wire 10Band ground black lead.4. Turn MASTER switch ON (refer to TM 9-2350-287-10).5. Check for 24 +3 vdc.6. Turn MASTER switch OFF (refer to TM 9-2350-287-10).Is voltage indicated?Replace circuit breaker no. 2 (para 7-11). Verify problem is solved.Repair wire 10B or replace harness12876405 (para 7-57). Verify problem issolved.CONTINUED FROM STEP BContinued on next page2-234