TM 9-2350-287-20-12-19. TROUBLESHOOTING CHART (continued)n. PERSONNEL HEATER (continued).(1) PERSONNEL HEATER FAILS TO OPERATE. Allother electrical systems operate (continued).CONTINUED FROM STEP AB.1. Place red multimeter lead in socket C andblack to ground.2. Turn MASTER switch ON (refer to TM 9-2350-287-10) and heater selector switch toHIGH or LOW.3. Check for 24 +3 vdc.4. Turn MASTER switch and heater selectorswitch OFF (refer to TM 9-2350-287-10).Is voltage present?Replace personnel heater (para16-7). Verify problem is solved.C. 1. Reconnect harness 12351544 to person-nel heater.2. Disconnect wiring harness 12351544 ataccessory control box.3. Place red multimeter lead on pin C ofaccessory control box and black lead toground.4. Turn MASTER switch ON and heater se-lector switch to HIGH or LOW (refer to TM 9-2350-287-10).5. Check for 24 +3 vdc.6. Turn MASTER switch and heater selectorswitch OFF (refer to TM 9-2350-287-10).Is voltaqe present?Continued on next page2-239