TM 9-2350-287-10FUEL FILL STRAINER AND FILL CAP MAINTENANCE1. Using hinged socket wrench handle and 9/16-inch socket, remove eight screws (5), lockwashers (4), and washers (3)and access plate (2) from hull.2.Unscrew fill cap (1) from fuel fill strainer (6).3.Make sure fill cap (1) is securely chained to strainer (6). If chain is damaged, notify Unit maintenance.WARNINGDiesel fuel Is flammable. Do not perform this procedure near fire, flame, or sparks. Injury or deathto personnel could result.4. Pull strainer (6) from access opening.5. Check strainer (6) for rips, excessive clogging, or other unserviceable conditions. If strainer (6) is unserviceable, notifyUnit maintenance.WARNING• Drycleaning solvent P-D-680 is TOXIC and flammable. Wear protective goggles and gloves; useonly in well-ventilated area; avoid contact with skin, eyes, and clothes, and do not breathe vapors.Keep away from heat or flame. Never smoke when using solvent; the flashpoint for type Idrycleaning solvent is 1 00°F (380C) and for type II is 138°F (50°C). Failure , JR do so may result Ininjury or death to personnel.• If personnel become dizzy while using drycleaning solvent, Immediately get fresh air andmedical help. If solvent contacts skin or clothing, flush with cool water. If solvent contacts eyes,Immediately flush eyes with water and get immediate medical attention.6. Remove breather cap (7) from fill cap (1). Clean breather cap (7) with drycleaning solvent (Item 13, Appendix D).3-24