TM 9-2350-277-34REPAIR POWER CONTROL ENCLOSURE, LEFT PANEL (M1068A3 ONLY) 0091 00THIS WORK PACKAGE COVERS:Disassembly (page 0091 00-1).Assembly (page 0091 00-5).INITIAL SETUP:Maintenance LevelDirect SupportTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0120 00, Item 62)Materials/PartsLocknut (40)Lockwasher (10)StrapPersonnel RequiredPower-Generation Equipment Repairer 52D10ReferencesSee your -10See your -20Equipment ConditionPower control enclosure assemblyremoved (see your -20).DISASSEMBLY1. Remove ten screws (11), lockwashers (12), and lower faceplate (9) from enclosure (10). Discard lockwashers.2. Remove two screws (5), locknuts (6), four washers (7), relay bail (3), relay XK2 (2), and relay socket (1) from left panel(4). Discard locknuts.3. Unplug relay socket (1) from relay XK2 (2).0091 00-1