TM 9-2350-277-34REPLACE POWER CONTROL ENCLOSURE POWER SUPPLIES (M1068A3 ONLY) —Continued0090 00INSTALLATION1. Install four isolators (13), 16 screws (15), and new locknuts (14) in enclosure (16).2. Install bracket (12), four new lockwashers (11), and screws (10) on four isolators (13).3. Lift power supply (4) into enclosure, have helper assist. Install circuits 10A and 10B leads with screw (8) on AC HIGHterminal of power supply (4).4. Install circuits 8B and 8C leads with screw (8) on AC LOW terminal of power supply (4).5. Install circuit 3Z lead with screw (8) on GND terminal of power supply (4).6. Lift power supply (3) into enclosure, have helper assist. Install circuit 10B lead with screw (6) on AC HIGH terminal ofpower supply (3).7. Install circuit 8C lead with screw (6) on AC LOW terminal of power supply (3).8. Install circuits 3Z and 3Y leads with screw (6) on GND terminal of power supply (3).0090 00-4