TM 9-2350-277-34REPLACE POWER CONTROL ENCLOSURE POWER SUPPLIES (M1068A3 ONLY) —Continued0090 009. Connect jumper cable (1) to J1 on power supply (2) and J1 on power supply (3).10. Connect circuits 31E and 31D (4) leads with nut (5) to positive terminal of power supply (2).11. Connect circuits 31C (6) and 31D (4) leads with nut (5) to positive terminal of power supply (3).12. Connect circuits 32D and 32E (7) leads with nut (5) to negative terminal on power supply (3).0090 00-5
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business