TM 9-2350-277-34
VEHICLE BATTERIES DISCHARGE WITH EXTERNAL AC POWER APPLIED
(M1068A3 ONLY)
0007 00
INITIAL SETUP:
Maintenance Level
Direct Support
Tools and Special Tools
General Mechanics Tool Kit (WP 0120 00, Item 62)
Digital Multimeter (WP 0120 00, Item 38)
Special Purpose Power Cable
(WP 0121 00, Figure 0121 00-3)
Personnel Required
Power-Generation Equipment Repairer 52D10
Helper (H)
References
See your -10
See your -20
TM 11-7010-256-12&P
M1068A3 wiring diagrams (see your -20)
Equipment Condition
Power control enclosure removed (see your -20)
Power control enclosure power supply cover
removed (see your -20)
Unit level troubleshooting completed (see your -20)
WARNING
HIGH VOLTAGE is used in the operation of this equipment.
DEATH ON CONTACT may result if personnel fail to observe safety precautions.
NEVER work on equipment unless at least one other person familiar with the operation and
hazards of the equipment is nearby. That person should also be familiar with giving first aid.
When an operator helps a mechanic, that operator must be warned about dangerous areas.
SHUT OFF POWER supply to equipment before beginning work. Make sure all external power
is off/disconnected.
BE CAREFUL not to contact high-voltage connections when installing or operating this
equipment.
0007 00-1