TM 9-2350-277-20-6
REPLACE AC POWER EXTENSION BOX A6 AND DC POWER EXTENSION BOX A9 AND
MOUNT (M1068A3 ONLY) Continued
0834 00
2.
Disconnect UPS cable W43 (4) from connector (5) on AC power extension box (6).
3.
Disconnect cable W10 (7) from connector (8) on DC power extension box (3).
4.
Disconnect cable W45 (9) from connector (10) on DC power extension box (3).
5.
Disconnect cable W7 (11) from connector (12) on AC power extension box (6).
6.
Remove eight locknuts (13), screws (14), and two power extension boxes (3) and (6) from mount (15). Discard locknuts.
7.
Remove four screws (16), washer (17), and mount (15) from work station (18).
0834 00-2