REMOVAL - TM-9-2350-277-20-6_118
REPLACE AC POWER EXTENSION BOX A6 AND DC POWER EXTENSION BOX A9 AND MOUNT (M1068A3 ONLY)
TM-9-2350-277-20-6 Carrier Personnel Full Tracked Armored M113A3 2350-01-219-7577 (EIC AE7) Carrier Command Post Light Tracked M577A3 2350-01-369-6085 (EIC AE7) Manual
Page Navigation
70
71
72
73
74
75
76
77
78
79
80
TM 9-2350-277-20-6
REPLACE TENT INTERFACE PANEL BOX ASSEMBLY A5 (M1068A3 ONLY) — Continued
0833 00
INSTALLATION
1.
Install tent interface panel (1) in carrier and secure with two catches (2).
2.
Connect W129P1 (3) to J137 (4) of tent interface panel (1).
3.
Connect W32P6 (5) to J7 (6) of tent interface panel (1).
4.
Connect W32P7 (7) to J8 (8) of tent interface panel (1).
5.
Connect W32P9 (9) to J9 (10) of tent interface panel (1).
6.
Connect W32P8 (11) to J10 (12) of tent interface panel (1).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0338 00).
END OF TASK
0833 00-3/4 blank