TM 9-2350-277-20-5REPLACE M14 NBC CABLES AND SWITCH ASSEMBLY (M1059A3 ONLY) 0799 00THIS WORK PACKAGE COVERS:Removal (page 0799 00-1).Installation (page 0799 00-3).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Materials/PartsLockwasher (4)Straps (3)Personnel RequiredUnit MechanicReferencesSee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Ramp lowered (see your -10)Battery ground strap disconnected (WP 0337 00)Drop instrument panel. See Replace Panel Mounts andGround Leads (WP 0295 00).REMOVALNOTEGround lead terminal may be either ring terminal end or split terminal end.1. Loosen or remove screw (1) on mount (2) and remove ground lead (3).2. Remove power cable and ground assembly (4) from air purifier (5).0799 00-1