TM 9-2350-277-20-5REPLACE M8A3 NBC AIR PURIFIER AND FRAME (M1059A3 ONLY) — Continued 0777 005. Loosen screw (12) on shock mount (6). Slide slotted end of ground cable (15) under screw (12). Tighten screw.6. Install air purifier (17) in frame (11). Secure with latch (18).7. Attach quick-disconnect fittings of hoses for driver’s station (19), commander’s station (20), and smoke operator’sstation (21) to air purifier (17).FOLLOW-THROUGH STEPS1. Connect battery ground strap (WP 0337 00).2. Adjust air purifier. See TM 3-6680-316-10 for procedure.3. Start engine (see your -10).4. Raise and lock ramp (see your -10).5. Stop engine (see your -10).END OF TASK0777 00-3/4 blank