TM 9-2350-277-20-5
REPLACE M8A3 AIR PURIFIER AND FRAME (M1059A3 ONLY) Continued
0778 00
8.
Remove eight screws (1), 16 washers (2), eight locknuts (3), and bracket (4) from welded mount (5). Discard locknuts.
9.
Remove eight screws (6), 16 washers (7), eight locknuts (8), and bracket (9) from four sponson supports (10).
Discard locknuts.
INSTALLATION
1.
Install bracket (9), eight screws (6), 16 washers (7), and eight new locknuts (8) on four sponson supports (10).
2.
Install bracket (4), eight screws (1), 16 washers (2), and eight new locknuts (3) on welded mount (5).
3.
Install four mounts (11), 16 screws (12), 32 washers (13), and 16 new locknuts (14) and (15) on bracket (9). Do not
tighten one outside locknut for ground lead connection.
0778 00-3