TM 9-2350-277-20-5REPLACE ADAPTER ACCESS PLATE TO GENERATOR ELECTRICALCABLE ASSEMBLY (M1059A3 ONLY)0761 00THIS WORK PACKAGE COVERS:Removal (page 0761 00-1).Installation (page 0761 00-3).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Personnel RequiredSignal Support System Specialist 31U10ReferencesSee your -10TM 3-1040-283-10TM 3-1040-283-20&PEquipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Circuit breaker CB1 OFF (TM 3-1040-283-10)Battery ground strap disconnected (WP 0337 00)Air pressure released from compressor reservoir(TM 3-1040-283-20&P)Inboard armor shield removed (WP 0771 00)Smoke generator assembly removed from bracket(WP 0755 00)REMOVALWARNINGBefore you do any maintenance, discharge all capacitors to ground or electrical shock couldinjure personnel.NOTELeft and right cable assemblies are replaced the same way.1. Disconnect cable assembly (1) from adapter access plate connector (2).0761 00-1