TM 9-2350-277-20-5REPLACE COOLANT HEATER AND PUMP UNIT — Continued 0728 00FOLLOW-THROUGH STEPS1. Install air cleaner (WP 0168 00).2. Connect battery ground strap (WP 0337 00), (WP 0338 00), or (WP 0339 00).3. Fill carrier cooling system (WP 0227 00).4. Open fuel tank shut off valves (see your -10).5. Open heater fuel shut off valve (see your -10).6. Start heater (see your -10). Check to make sure heater is installed right. Check for leaks. Turn heater off.7. Close power plant access door (see your -10).8. Raise trim vane (see your -10).9. Start engine (see your -10).10. Raise and lock ramp (see your -10).11. Stop engine (see your -10).END OF TASK0728 00-8