TM 9-2350-277-20-5REPLACE COOLANT HEATER AND PUMP UNIT — Continued 0728 007. Loosen clamp (12). Disconnect hose (13) from elbow (14).8. Loosen clamp (15). Disconnect hose (16) from tee (17).9. Loosen clamp (18). Disconnect exhaust pipe (19) from elbow hose (20).10. Remove heater (21), pump (22), and bracket (23) from carrier as an assembly.0728 00-4