TM 9-2350-277-20-5REPLACE COOLANT HEATER EXHAUST ELBOW AND PIPES 0724 00THIS WORK PACKAGE COVERS:Removal (page 0724 00-1).Installation (page 0724 00-2).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Materials/PartsGasketPersonnel RequiredUnit MechanicReferencesSee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Ramp lowered (see your -10)Trim vane lowered (see your -10)Power plant access door open (see your -10)Air cleaner removed (WP 0168 00)REMOVAL1. Loosen three clamps (1) on upper exhaust pipe (2), on lower exhaust pipe (3), and on exhaust elbow (4).0724 00-1