TM 9-2350-277-20-5REPLACE HYDRAULIC RESERVOIR0671 00THIS WORK PACKAGE COVERS:Removal (page 0671 00-1).Installation (page 0671 00-3).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Materials/PartsLocknut (3)Suitable containerPersonnel RequiredUnit MechanicReferencesSee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Power plant rear access panel removed (see your -10)Driver’s power plant access panelremoved (see your -10)REMOVALWARNINGFire Resistant Hydraulic fluid (FRH) is toxic if absorbed through skin or ingested.Do not service hydraulic system when FRH is hot or pressurized.Wear gloves and avoid contact with skin.If FRH contacts skin, wash immediately with soap.If FRH gets into eyes, wash with lots of water for 15 minutes and get medical attention.If FRH is swallowed, get medical attention.WARNINGUnlocked ramp can fall open suddenly. Personnel can be killed or injured. Lower ramp beforedisconnecting hydraulic lines.CAUTIONDo not allow hydraulic fluid to spill or drain on the generator. Cover generator withappropriate material to prevent damage.0671 00-1