TM 9-2350-277-20-5
REPAIR HYDRAULIC RESERVOIR
0672 00
THIS WORK PACKAGE COVERS:
Disassembly (page 0672 00-1).
Assembly (page 0672 00-3).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Materials/Parts
Sealing compound WP 0928 00, Item 56
Lockwasher (4)
Preformed packing
Preformed packing (2)
Preformed packing (2)
Personnel Required
Unit Mechanic
Equipment Condition
Hydraulic reservoir removed (WP 0671 00)
DISASSEMBLY
WARNING
Fire Resistant Hydraulic fluid (FRH) is toxic if absorbed through skin or ingested.
Do not service hydraulic system when FRH is hot or pressurized.
Wear gloves and avoid contact with skin.
If FRH contacts skin, wash immediately with soap.
If FRH gets into eyes, wash with lots of water for 15 minutes and get medical attention.
If FRH is swallowed, get medical attention.
1.
Remove cap (1), elbow (2), and preformed packing (3) from reservoir (4). Discard packing.
2.
Remove liquid sight indicator (5) and preformed packing (6). Discard packing.
3.
Remove plug (7) and preformed packing (8). Discard packing.
4.
Remove breather (9) from top of reservoir.
0672 00-1