TM 9-2350-277-20-5REPAIR HYDRAULIC RESERVOIR0672 00THIS WORK PACKAGE COVERS:Disassembly (page 0672 00-1).Assembly (page 0672 00-3).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Materials/PartsSealing compound WP 0928 00, Item 56Lockwasher (4)Preformed packingPreformed packing (2)Preformed packing (2)Personnel RequiredUnit MechanicEquipment ConditionHydraulic reservoir removed (WP 0671 00)DISASSEMBLYWARNINGFire Resistant Hydraulic fluid (FRH) is toxic if absorbed through skin or ingested.Do not service hydraulic system when FRH is hot or pressurized.Wear gloves and avoid contact with skin.If FRH contacts skin, wash immediately with soap.If FRH gets into eyes, wash with lots of water for 15 minutes and get medical attention.If FRH is swallowed, get medical attention.1. Remove cap (1), elbow (2), and preformed packing (3) from reservoir (4). Discard packing.2. Remove liquid sight indicator (5) and preformed packing (6). Discard packing.3. Remove plug (7) and preformed packing (8). Discard packing.4. Remove breather (9) from top of reservoir.0672 00-1