TM 9-2350-277-20-5
REPLACE HYDRAULIC RESERVOIR Continued
0671 00
INSTALLATION
WARNING
Fire Resistant Hydraulic fluid (FRH) is toxic if absorbed through skin or ingested.
Do not service hydraulic system when FRH is hot or pressurized.
Wear gloves and avoid contact with skin.
If FRH contacts skin, wash immediately with soap.
If FRH gets into eyes, wash with lots of water for 15 minutes and get medical attention.
If FRH is swallowed, get medical attention.
NOTE
Care must be taken not to contaminate the hydraulic system.
1.
Install reservoir (1) and secure to brackets (2)(3) with three screws (4), six washers (5), and three new locknuts (6).
2.
Connect two return hoses (7) to elbows (8) on side of reservoir (1).
3.
Connect pump to strainer hose (9) to bottom of reservoir (1).
4.
Fill hydraulic reservoir (WP 0155 00).
0671 00-3