TM 9-2350-277-20-5SERVICE HYDRAULIC RESERVOIR0669 00THIS WORK PACKAGE COVERS:Removal (page 0669 00-1).Cleaning, Inspection, and Repair (page 0669 00-2).Installation (page 0669 00-3).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Materials/PartsCleaning Compound (WP 0928 00, Item 19)Lockwasher (4)Preformed packingPersonnel RequiredUnit MechanicReferencesSee your -10Equipment ConditionRamp lowered (see your -10)Power plant upper rear access panelremoved (see your -10)Driver’s power plant access panelremoved (see your -10)Hydraulic reservoir removed (WP 0671 00)REMOVALWARNINGFire Resistant Hydraulic fluid (FRH) is toxic if absorbed through skin or ingested.Do not service hydraulic system when FRH is hot or pressurized.Wear gloves and avoid contact with skin.If FRH contacts skin, wash immediately with soap.If FRH gets into eyes, wash with lots of water for 15 minutes and get medical attention.If FRH is swallowed, get medical attention.CAUTIONHydraulic lines, tubes, valves, and components can be damaged. Install covers on disconnectedhydraulic lines, tubes, valves, and components during maintenance. Use tape, cloth, cardboard,or any appropriate material to prevent damage to components or accidental hydraulic spills.0669 00-1