TM 9-2350-277-20-5
SERVICE HYDRAULIC RESERVOIR
0669 00
THIS WORK PACKAGE COVERS:
Removal (page 0669 00-1).
Cleaning, Inspection, and Repair (page 0669 00-2).
Installation (page 0669 00-3).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Materials/Parts
Cleaning Compound (WP 0928 00, Item 19)
Lockwasher (4)
Preformed packing
Personnel Required
Unit Mechanic
References
See your -10
Equipment Condition
Ramp lowered (see your -10)
Power plant upper rear access panel
removed (see your -10)
Drivers power plant access panel
removed (see your -10)
Hydraulic reservoir removed (WP 0671 00)
REMOVAL
WARNING
Fire Resistant Hydraulic fluid (FRH) is toxic if absorbed through skin or ingested.
Do not service hydraulic system when FRH is hot or pressurized.
Wear gloves and avoid contact with skin.
If FRH contacts skin, wash immediately with soap.
If FRH gets into eyes, wash with lots of water for 15 minutes and get medical attention.
If FRH is swallowed, get medical attention.
CAUTION
Hydraulic lines, tubes, valves, and components can be damaged. Install covers on disconnected
hydraulic lines, tubes, valves, and components during maintenance. Use tape, cloth, cardboard,
or any appropriate material to prevent damage to components or accidental hydraulic spills.
0669 00-1