TM 9-2350-277-20-4REPAIR NONSKID SURFACES (M981A3 ONLY) — Continued 0605 00c. Apply cleaning compound mixture and allow to remain on surface 5 to 10 minutes. Scrub with a non-metallicbrush.NOTERinse cleaning compound before it dries or area will streak and not be cleaned effectively.d. Rinse all areas thoroughly with running water.PAINTINGPRETREAT AND PRIME1. For small areas, touch up pretreatment and primer using corrosion kit.WARNINGMixing acid and resin components can be hazardous. Always add acid to resin. Do not addresin to acid. If resin component is added to acid, a violent chemical reaction may result,injuring personnel. To avoid injury to personnel or damage to equipment, always pour acidcomponent slowly into the resin component.NOTEMix only enough coating compound for immediate use.2. Pretreat cleaned area with coating compound as follows:a. Before mixing, thoroughly shake both acid and resin components to incorporate any settled material.b. Add one part acid slowly to four parts resin. Stir continuously until mixed.c. Apply coating compound with a brush. When dry, coating thickness should be 0.012 to 0.015 inch (0.3 to 0.4 mm).d. Allow coating to dry for one to four hours. Coating is dry when it resists removal with fingernail.WARNINGBreathing vapors from zinc chromate primer may be hazardous. Do not breathe vapors. Useprimer in a well ventilated area.3. Apply zinc chromate primer to the area as follows:a. Stir primer in its original container until thoroughly mixed. Mix one part primer with one part lacquer thinner.0605 00-2