TM 9-2350-277-20-4REPLACE POWER PLANT DOOR COMBAT LOCK — Continued 0473 00INSTALLATION1. (H) Install bolt (1) in place from outside carrier through access to power plant compartment.2. From inside driver’s compartment, install spring (2) and handle (3) on bolt (1). Secure with new drive pin (4).3. Connect four wiring harnesses (5) to bulkhead in driver’s compartment.FOLLOW-THROUGH STEPS1. Connect battery ground strap(WP 0337 00), (WP 0338 00), or (WP 0339 00).2. Close power plant door (see your -10).3. Connect and raise trim vane (see your -10).END OF TASK0473 00-3/4 blank