TM 9-2350-277-20-3
REPLACE UTILITY OUTLET LEAD ASSEMBLY (M577A3 AND M1068A3 ONLY)
Continued
0377 00
INSPECTION-ACCEPTANCE AND REJECTION CRITERIA
INSPECTION AND REPAIR
1.
Check connectors. Repair as needed (WP 0382 00).
INSTALLATION
NOTE
Lead assembly is banded as circuit 37 at master switch panel and circuit 38 at instrument panel.
Make sure it is installed properly.
1.
Connect lead assembly (1) to circuit 38 lead (4) at instrument panel (5).
2.
Connect lead assembly (1) to circuit 37 lead (2) at master switch panel (3).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0338 00).
2.
Turn MASTER SWITCH to ON to check that lead assembly is installed properly (see your -10).
3.
Turn MASTER SWITCH to OFF (see your -10).
END OF TASK
0377 00-2