TM 9-2350-277-20-2
REPLACE RADIATOR OUTLET TUBE AND HOSES Continued
0233 00
3.
Apply sealing compound to mounting surfaces of new gasket (6).
4.
Install adapter (7) with new gasket (6) on engine. Secure with two screws (8), washers (9), and new lockwashers (10).
5.
Install hose (11) and tube (12) on radiator outlet elbow (3). Secure with two clamps (13).
6.
Install radiator outlet tube (14) and two hoses (15) on tube (12) and adapter (7). Secure with four clamps (16).
7.
Secure radiator outlet tube (14) to support bracket (17) with two clamps (18).
8.
Install auxiliary tank outlet hose (19) on radiator outlet tube (14). Secure with clamp (20).
9.
Install elbow (21) on radiator outlet tube (14). Install drain cock (22) on elbow (21).
10. Install drain hose (23) on drain cock (22). Secure with clamp (24).
FOLLOW-THROUGH STEPS
1.
Install power plant (WP 0156 00).
2.
Install power plant rear access panels (see your -10).
3.
Install drivers power plant access panel (see your -10).
END OF TASK
0233 00-3/4 blank