TM 9-2350-277-20-2
REPLACE RADIATOR OUTLET TUBE AND HOSES
0233 00
THIS WORK PACKAGE COVERS:
Removal (page 0233 00-1).
Installation (page 0233 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Materials/Parts
Sealing compound (WP 0928 00, Item 56)
Gasket
Gasket
Key washer (2)
Lockwasher (2)
Personnel Required
Unit Mechanic
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Master switch OFF (see your -10)
Drivers power plant access panel
removed (see your -10)
Power plant rear access panels removed (see your -10)
Power plant removed (WP 0156 00)
REMOVAL
1.
Loosen clamp (1) securing drain hose (2) to drain cock (3). Remove hose and clamp.
2.
Remove drain cock (3) from elbow (4). Remove elbow (4) from radiator outlet tube (5).
3.
Loosen clamp (6) securing auxiliary tank outlet hose (7) to radiator outlet tube (5). Remove clamp and hose.
4.
Remove two clamps (8) securing radiator outlet tube (5) to tube support bracket (9).
5.
Loosen four clamps (10) securing two hoses (11) and radiator outlet tube (5) to adapter (12) and tube (13). Remove
clamps, hoses, and tube.
6.
Loosen two clamps (14) securing tube (13) and hose (15) to radiator outlet elbow. Remove clamps, hose, and tube.
0233 00-1