TM 9-2350-277-20-2PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDINGLUBRICATION INSTRUCTIONS — Continued0155 00ITEMNO.INTERVALMAN-HOURITEM TO BECHECKED ORSERVICEDCREWMEMBERPROCEDUREEQUIPMENTNOT READY/AVAILABLEIF:WARNINGLowering ramp could injure personnel.Make sure no one is in ramp zone beforeyou lower the ramp. Unlocked ramp canfall open suddenly. Personnel can be killedor injured. Ramp system and hull can getdamaged if ramp unlocks when carrier isin operation. Do not operate carrier iflocks do not secure ramp properly. Keepaway from ramps that have come openduring carrier operation.d. Tighten or replace cracked or leaky fitting onramp cylinder and ramp control.Pumps fail tooperate orraise ramp.e. Replace leaky ramp cylinder (WP 0656 00).f. Replace tubes or hoses that are cracked,crimped, or worn (WP 0660 00) or(WP 0668 00).g. Drain hydraulic system tank and service strainerevery 1500 miles, semi-annually or whenhydraulic fluid is changed to FRH.1) Lower ramp (see your -10).2) Place a suitable container under drain elbowon bottom of tank.3) Remove drain cap and preformed packingfrom drain elbow. Discard packing.4) Service hydraulic system tank breather(WP 0670 00) and strainer (WP 0669 00).5) Install drain cap with new preformedpacking on drain elbow.6) Remove fill plug and preformed packingfrom top of tank.0155 00-117