TM 9-2350-277-20-2PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDINGLUBRICATION INSTRUCTIONS — Continued0155 00ITEMNO.INTERVALMAN-HOURITEM TO BECHECKED ORSERVICEDCREWMEMBERPROCEDUREEQUIPMENTNOT READY/AVAILABLEIF:1) Remove driver’s power plant access panel(see your -10).2) Place suitable container under primary fuelfilter. Open drain cock and drain water andsediment from primary fuel filter. Whenclean fuel starts to drain out, close draincock.3) Repeat Step 67b2 for secondary fuel filter.4) Check for fuel leaks at primary andsecondary fuel filters while engine isrunning. If leak is found, remove and installprimary and secondary fuel filter elementsand check for proper fit and seal(WP 0202 00).0155 00-114