TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS Continued
0155 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
68
Semi-
Annual
1.0
Hydraulic
System
WARNING
Hydraulic fluid is poison and can be
absorbed through your skin. Wash off
hydraulic fluid that contacts your skin.
Fire resistant hydraulic (FRH) fluid may
contain Tricresyl Phosphate which, if
taken internally, can produce paralysis.
Hydraulic fluid may be absorbed through
the skin. Wear long sleeves, gloves,
goggles, and face shield. If FRH gets in
eyes, wash them immediately and get
medical aid immediately. If FRH gets in
eyes, wash them immediately and get
medical aid immediately. If FRH gets on
skin, thoroughly wash with soap and
water. Wash hands thoroughly prior to
eating or smoking.
a. Tighten or replace cracked or leaking fittings on
hydraulic reservoir or pump (WP 0655 00) or
(WP 0672 00).
Any hydraulic
leaks, fluid not
visible on
sight gauge,
cracked,
broken,
crimped,
missing, or
loose
hardware.
b. Replace leaky pump (WP 0655 00).
c. Tighten tubes or hoses or leak (WP 0668 00).
0155 00-115