TM 9-2350-277-20-1
NO POWER TO AC CIRCUITS (M1068A3 ONLY)Continued
0107 00
10Y
1. Set BLACKOUT ENABLE switch to down position.
2. Set AC LIGHTS switch in upward position.
3. Measure resistance between terminal 2 (1) and terminal 1 (2) of
circuit breaker CB17 (3).
4. Does multimeter read 0 ohms?
YES
NO
10YN
1. Replace circuit breaker CB17
(WP 0828 00).
2. Verify no faults found.
0107 00-11