TM 9-2350-277-20-1
NO POWER TO AC CIRCUITS (M1068A3 ONLY)Continued
0107 00
6Y
1. Measure resistance of circuit 19B from terminal 2 (1) of switch
S1 (2) and terminal A2 (3) of relay K5 (4).
2. Measure resistance of circuit 20A from terminal 3 (5) of switch
S1 (2) and terminal A3 (6) of relay K5 (4).
3. Does multimeter read 0 ohms?
YES
NO
6YN
1. Faulty leads 19B and/or lead 20A.
Beyond unit maintenance repair.
2. Notify supervisor.
7Y
1. Remove leads 19A and 19B from switch S1 position 2.
2. Measure resistance with switch S1 (1) in both up and down
positions.
3. Does multimeter read 0 ohms when switch is down and infinite
ohms when switch is up?
YES
NO
7YN
1. Replace switch S1 (WP 0828 00).
2. Verify no faults found.
0107 00-8