TM 9-2350-277-20-1
POWER CONTROL ENCLOSURE A1 DC INPUT/OUTPUT INOPERATIVE (M1068A3
ONLY)—Continued
0090 00
C2Y
1. Set MASTER SWITCH to OFF.
2. Remove cable W29 plug P1 (1) from adapter T2 plug P2 (2).
3. Measure
resistance
between adapter T2 plugs P2 (2) and P1 (3).
4. Does
multimeter
read 0 ohms?
YES
NO
C2YN
1. Replace adapter T2 (WP 0850 00).
2. Verify no faults found.
C3Y
1. Remove cable W29 plug P2 (1) from cable W38 plug P6 (2).
2. Measure
resistance
between plugs P2 (1) and P1 (3) of cable
W29.
3. Does
multimeter
read 0 ohms?
YES
NO
C3YN
1. Replace cable W29 (WP 0850 00).
2. Verify no faults found.
0090 00-13