TM 9-2350-277-20-1
BATTERY/GENERATOR INDICATOR MALFUNCTIONS
0051 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Multimeter (WP 0926 00, Item 30)
Personnel Required
Unit Mechanic
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
T
1. Remove instrument panel for access (WP 0295 00).
2. Remove circuit 27E plug (1) from battery generator indicator jack
(2).
3. Remove circuit 10 plug (3) from instrument panel circuit breaker
jack (4).
4. Check continuity between circuit 27E plug (1) and circuit 10 plug
(3).
5. Read multimeter. Is there continuity?
YES
NO
TN
1. Replace harness 10933038
(WP 0289 00).
2. Verify no faults found.
Y
1. Replace BATTERY/GENERATOR indicator (WP 0285 00).
2. Verify no faults found.