TM 9-2350-277-20-1
GENERATOR MALFUNCTIONS AS INDICATED BY BATTERY/GENERATOR
INDICATORContinued
0025 00
B6Y
1. Replace circuit 6 lead (WP 0356 00), (WP 0357 00), or
(WP 0358 00).
2. Verify no faults found.
CY
1. Has regulator been adjusted?
YES
NO
CYN
1. Adjust voltage regulator
(WP 0256 00).
2. Verify no faults found.
C2Y
1. Remove harness 12349873 plug (1) from generator field switch
(2).
2. Start engine (see your -10).
3. Measure resistance across switch (2) pins (3) and (4) with engine
idling. Use VTM.
4. Does VTM read 0 ohms?
YES
NO
C2YN
1. Stop engine (see your -10).
2. Replace generator field switch
(WP 0323 00).
3. Verify no faults found.
0025 00-6