TM 9-2350-277-20-1
GENERATOR MALFUNCTIONS AS INDICATED BY BATTERY/GENERATOR
INDICATORContinued
0025 00
4Y
1. Disconnect battery ground strap/lead(s) (WP 0337 00),
(WP 0338 00), or (WP 0339 00).
2. Remove harness 12349873 plug (1) from generator jack (2).
3. Inspect harness plug pins for corrosion or damage.
4. Is plug free from corrosion and damage?
YES
NO
4YN
1. Replace harness. (See Table of
Contents).
2. Verify no faults found.
5Y
1. Replace generator (WP 0255 00).
2. Verify no faults found.
AY
1. Measure resistance between regulator housing (1) and ground.
Use VTM.
2. Does VTM read 0 ohms?
YES
NO
AYN
1. Remove regulator (WP 0257 00) and
clean ground contact (bolted
surface).
2. Install regulator (WP 0257 00).
3. Verify no faults found.
A2Y
1. Has regulator been adjusted?
YES
NO
A2YN
1. Adjust voltage regulator
(WP 0256 00).
2. Verify no faults found.
0025 00-2